ETG MCA100 SYN 19″ – Rack Syngas Analyzer
Rack 19" syngas analyzer

Rack-mount syngas analyzer, compact 19" 4U

Methane (CH4) · Carbon dioxide (CO2) · Carbon monoxide (CO) · Hydrogen (H2) · Oxygen (O2) · Syngas analyzer · 19" rack

ETG MCA100 SYN 19-inch rack-mount syngas analyzer with 7-inch touch screen

ETG MCA100 SYN 19" is a 19" 4U rack analyzer for syngas from gasification and pyrolysis. NDIR measures CH4, CO2 and CO, a TCD measures H2 and an electrochemical cell measures O2, with N2 and calorific value calculated continuously.

Temperature and pressure compensation virtually eliminate zero drift after warm-up. Compact and easy to integrate in control rooms, shelters and skids.

483 × 177 × 550
Dimensions (mm)
19" 4U
11 kg
Compact chassis
Rack or tabletop
5 gases
CH₄ · CO₂ · CO · H₂ · O₂
NDIR + TCD + electrochemical
7" touch
Screen
Ethernet · USB · Wi-Fi
Key features

Designed for control rooms, shelters and skids

01

Rack or tabletop

Standard 19" 4U chassis with 6 mm rapid pneumatic fittings, for rack rails or tabletop use and easy integration into control rooms, shelters and skids.
02

Heating value in real time

N2 and calorific value are calculated continuously with a proprietary algorithm, with no extra sensor.
03

Expandable and connected

Multipoint sampling system, internal pump, CnHm / H2S / NH3 measurement, automatic zero and digital outputs. Ethernet, USB and Wi-Fi, 4-20 mA as standard, .csv data logging.
Where it fits

Where the ETG MCA100 SYN 19" is used

Process efficiency

Gasification and pyrolysis

Continuous CO, H2, CH4 and CO2 monitoring with real-time calorific value, for gasifier tuning and fuel-gas quality control.
Metallurgy

Metallurgical and heat-treatment furnaces

Continuous CO, CO2, CH4, H2 and O2 measurement of furnace and process atmospheres, for atmosphere control and product quality.
System integration

OEM skid integration and control rooms

Rear-panel connections, Ethernet, Wi-Fi, USB and 4-20 mA make integration into shelters and syngas systems straightforward.
Tar, dust and water vapour foul sample lines and sensors. When they are present in the syngas, install the ETG PSS100 sample treatment system upstream of the analyzer: it removes tar, dust and water before the gas reaches the MCA100 SYN 19".
Technical data

ETG MCA100 SYN 19": key specifications

FeatureDetail
Power supply230 VAC 50 Hz (other mains voltages/frequencies on request)
Power consumptionMax 40 W · typical 30 W
Display7" touch screen
ConnectivityEthernet, USB, Wi-Fi
Communication protocol4-20 mA (standard when no industrial protocol is installed); Modbus, Profibus, Profinet (optional)
Data availability.csv via USB or remote folder (SMB)
Dimensions / weight483 × 177 × 550 mm (19" 4U) · 11 kg
Mounting / certification19" rack or tabletop · CE
Sample conditioningFor syngas with tar, dust or water, use the ETG PSS100 sample treatment system upstream
Sample pumpOptional (internal)
Sample flow / fittings0.5–1.5 l/min · rapid fitting, 6 mm O.D.
Sample gas0.1–0.3 bar · 5–40 °C non-condensing · dry, dust-free, oil-free
Operating conditions0–50 °C · up to 95% RH non-condensing · −300 to 3000 m
Warm-up30 s ready · 3 min usable · 30 min full performance
CalibrationManual zero and span (automatic zero with ambient air optional)

Analytical performance

GasPrincipleRangeResponse
Methane (CH4)NDIR0 – 100% volT90 & T10 < 10 s
Carbon dioxide (CO2)NDIR0 – 100% volT90 & T10 < 10 s
Carbon monoxide (CO)NDIR0 – 100% volT90 & T10 < 10 s
Hydrogen (H2)TCD, automatically corrected0 – 10 / 20 / 50 / 100% volT90 & T10 < 20 s
Oxygen (O2)Electrochemical (ECD)0 – 25% vol< 30 s
Hydrocarbons (CnHm) – optionalNDIR0 – 5 / 10 / 20% volT90 & T10 < 10 s
Hydrogen sulphide (H2S) – optionalNDUVRanges on requestOn request
Ammonia (NH3) – optionalECD0 – 200 / 1000 ppmOn request

Resolution 0.01%. Accuracy ±1% F.S. for CH4, CO2, CO and CnHm, ±2% F.S. for H2 and O2. N2 and calorific value are calculated continuously with a proprietary algorithm (standard). Other gases (including paramagnetic O2) and other ranges are available on request. O2 response: < 30 s from ambient air to 0.15% O2.

Software & connectivity

ETG software: touch interface, trends and remote access

A 7" touch interface shows live values, trends and alarms. Data are logged in .csv and the display can be viewed remotely via VNC. Analyzers fitted with the optional Modbus, Profibus or Profinet protocols integrate with SCADA systems and offer two-way communication, so they can also be controlled from SCADA when needed.

ETG MCA software home screen with live gas readings
ETG MCA software trend screen with gas concentration charts

Options and accessories

CnHm by NDIRH₂S by NDUVNH₃ by ECDParamagnetic O₂ sensorETG PSS100 and heated lineInternal sample pumpMultipoint sampling systemAutomatic zero with ambient airDigital outputs (4 alarms)Modbus / Profibus / ProfinetOther mains voltages/frequencies
The ETG syngas series

Three formats for syngas analysis

ETG syngas analyzers share the same measurement technology, the same software and the same performance, and differ in format: pick the one that fits your plant or your measurement campaign.

Syngas series

ETG 6500 SYN – wall-mount

Stainless-steel wall-mount analyzer with Peltier chiller and integrated gas cleaning for raw syngas. Discover it →
Syngas series

ETG MCA100 SYN P – portable

Rugged portable analyzer with internal pump for plant audits and commissioning. Discover it →

Syngas with tar, dust or water vapour? Pair the analyzer with the ETG PSS100 sample treatment system.

Request information about the ETG MCA100 SYN 19" analyzer
Tell us about your skid or control room: we will help you choose the right configuration.
Contact ETG