ETG 6900 P – Portable TDL Laser Gas Analyzer
Portable TDL laser gas analyzer

Portable TDL laser gas analyzer for on-site measurements

Portable TDL laser gas analyzer · mains-powered · rugged case · field measurements · ppm-level detection

ETG 6900 P portable TDL laser gas analyzer in rugged case with heated line and probe

ETG 6900 P is the portable version of the TDL laser gas analyzer developed by ETG Risorse e Tecnologia: a rugged case for selective measurements of specific gases, down to ppm levels, wherever the plant or the site requires them.

It is mains-powered, with a 7" touch screen, .csv data logging and connection via Ethernet or Wi-Fi. The heated-cell (-H) configuration, with heated line and optional heated probe, makes it suitable for hot, wet gases.

TDLAS
Tunable diode laser
Selective, real-time detection
7.2 kg
Rugged case
625 × 500 × 297 mm
Touch 7"
Screen
Ethernet · USB · Wi-Fi
190 °C
Heated cell (-H)
For hot, wet gases
Key features

Built for measurements on site

01

Portable

Rugged case, 625 × 500 × 297 mm and 7.2 kg; IP54 optional.
02

Hot and wet gases

Heated-cell (-H) configuration at 190 °C with heated pump, heated line and optional heated probe.
03

Connected

Ethernet and Wi-Fi as standard; optional 4-20 mA outputs, digital alarm outputs and industrial protocols.
Where it is used

Applications of the ETG 6900 P gas analyzer

Emissions & processes

Industrial emissions monitoring

Selective, real-time measurement of NH3, HCl and H2O in flue gas and process streams, with the heated-cell (-H) configuration for hot, wet gases. See industrial emissions monitoring.
Environment

Greenhouse gas monitoring

Low detection limits for CH4 and CO2, to keep fugitive emissions from landfills, networks and plants under control. See greenhouse gas emissions.
Energy

Fugitive methane emissions

Locating fugitive CH4 emission points in biogas plants and landfills, and studying CH4 emissions (e.g. university research).

Many other applications

Leak checks, gas purity control, CO2 quality control, process monitoring and research: the laser sensor is chosen for the compound to be measured.

Measuring hot, wet gas on site? The heated-cell (-H) configuration keeps the cell at 190 °C and accepts up to 30% vol of water vapour. It includes a heated sample pump (if a pump is installed) and a heated sample line, which is mandatory; a heated portable probe is available as an option.
Technical data

ETG 6900 P: key specifications

FeatureDetail
Power supplyMains: 230 VAC 50 Hz (other mains voltages/frequencies on request)
Power consumption70 W (non-heated cell) / 170 W (heated cell) · heated line 80 W/m · heated probe 80 W
Display / connectivity7" touch screen; Ethernet, Wi-Fi, USB
Communication protocol4-20 mA analog outputs (optional); 4 digital alarm outputs (optional); industrial protocols (Modbus, Profibus, Profinet…) (optional): SCADA integration with bidirectional communication (control from SCADA possible)
Data availability.csv format, downloadable via USB or remote folder (SMB)
Dimensions (L × W × D) / weight625 × 500 × 297 mm · 7.2 kg
RatingIP54 (optional)
CertificationCE
Sample pumpOptional (heated pump with the heated cell)
Sample flow / fittings0.1 to 3 l/min (non-heated cell); 1.5 to 5 l/min (heated cell) · for 6 mm O.D. tubing
Laser sensorsOne laser sensor, selected for the gases to be measured

Operating conditions

FeatureDetail
Sample gas800-1100 mbar; ambient temperature (non-heated cell) or up to 190 °C (heated cell, -H)
Sample gas characteristicsOil-free, dust-free; non-condensing (non-heated cell) or up to 30% vol H2O (heated cell)
Measuring cell temperatureNot heated; 190 °C with heated cell (-H), up to 220 °C
Ambient conditions0 to 50 °C; ≤ 95% RH non-condensing; -300 to 3000 m
CalibrationZero with N2; span with a cylinder of the target gas
Warm-up time30 s to start; usable after about 3 min; stable after about 30 min (heated cell: about 30 min to reach 190 °C, fully stable after about 60 min)

Analytical performance

FeatureDetail
Measuring principleTDLAS (tunable diode laser absorption spectroscopy)
Accuracy±2% of full scale (or ±2 ppm / 2% of reading, whichever is greater)
CH40-100 ppm up to 0-40,000 ppm · precision ≤ 0.8 ppm or 0.6% of reading · T90 ≤ 1.8 s
CH4 + CO2CH4 0-100 ppm, CO2 0-10% vol · precision CH4 ≤ 0.8 ppm, CO2 ≤ 2,000 ppm · T90 ≤ 30 s (0.3 l/min)
CH4 + C2H6CH4 0-100 ppm up to 0-40,000 ppm, C2H6 0-1,000 ppm · T90 CH4 ≤ 1.8 s, C2H6 ≤ 15 s
NH3 + H2ONH3 0-100 ppm, H2O 0-5% vol · precision NH3 ≤ 0.8 ppm, H2O ≤ 0.2% vol · T90 ≤ 3 s
C2H2 + H2OC2H2 0-100 ppm (linear up to 500 ppm), H2O 0-10% vol · T90 60 s (0.6 l/min)
H2O (-H)0-30% vol · accuracy ±0.5% vol · precision 0.2% vol (1 s) / 0.1% vol (10 s) · T90 2 s (3 l/min)
NH3 + H2O (-H)NH3 0-100 ppm (min. range 0-20 ppm), H2O 0-30% vol · NH3 precision 1.8 ppm (1 s) / 0.8 ppm (10 s) · T90 2 s (3 l/min)
HCl + H2O (-H)HCl 0-50 ppm (linear up to 500 ppm, no precision guarantee), H2O 0-30% vol · detection limit < 0.4 ppm, precision < 0.6 ppm (10 s avg.), accuracy ±2 ppm · T90 20 s (3 l/min)

Ranges, precision and response times as specified for each laser sensor. The heated-cell (-H) configuration includes a heated measuring cell (190 °C), a heated sample pump (if a pump is installed) and a heated sample line (mandatory).

Options and accessories

Sample pumpHeated sample pumpHeated cell (-H)Heated lineHeated portable probe4-20 mA outputsDigital alarm outputsIndustrial protocols (Modbus / Profibus / Profinet)IP54
How it works

How TDL laser spectroscopy works

TDLAS (tunable diode laser absorption spectroscopy) tunes a diode laser across a very narrow absorption line of the target gas: the laser line is much narrower than the absorption line of the gas, so the resolution is much higher than with other technologies, and the analyzer detects specific compounds selectively, in real time and with minimal interference, even at ppm concentrations.

The laser sensor is chosen for the gases to be measured. TDL technology does not require frequent calibrations, which keeps maintenance and running costs low.

ETG 6900 series

Three formats, one TDL laser technology

The ETG 6900 uses the same laser technology in every format: pick the one that fits your application.

ETG 6900 series

ETG 6900 19" – rack

19" 4U rack analyzer for fixed installations and continuous measurement. Discover →
ETG 6900 series

ETG 6900 WM – wall-mounted

Wall-mounted cabinet for plants, with up to three laser sensors. Discover →

Need to measure many gases at the same time? See the ETG 9500 FTIR multicomponent analyzer.

Request information about the ETG 6900 P
Tell us about your application: we will help you choose the laser sensor, the configuration and the options best suited to it.
Contact ETG