Compact portable TDL laser methane analyzer for leak detection and field work
Portable TDL laser methane analyzer · CH4 from ppm to % vol · battery-powered · compact case · leak detection

ETG 6900 P CH4 is the compact portable TDL laser analyzer dedicated to methane (CH4), developed by ETG Risorse e Tecnologia for stand-alone field work such as methane leak detection.
A tunable diode laser measures CH4 selectively and in real time, from ppm levels up to % vol, with a response time of 1.8 seconds or less. It is battery-powered and ready to use (Plug&Play), with the sampling pump included, a 7" touch screen, .csv data logging and connection via Ethernet or Wi-Fi.
Built for methane measurements in the field
Selective CH4
Autonomous
Ready to use
Applications of the ETG 6900 P CH4 methane analyzer
Methane leak detection
Greenhouse gas monitoring
Biogas and biomethane plants
Many other applications
Gas purity checks, process monitoring and research where a fast, portable methane reading is needed.
ETG 6900 P CH4: key specifications
| Feature | Detail |
|---|---|
| Power supply | Rechargeable 12 VDC battery, up to 8 h; charging time about 3 h |
| Power consumption | 15 W (max) / 10 W (typ) |
| Display | 7" touch screen |
| Connectivity | Ethernet, Wi-Fi, USB |
| Data availability | .csv format, downloadable via USB or remote folder (SMB) |
| Dimensions (L × W × D) / weight | 339 × 295 × 152 mm · 2.5 kg |
| Rating | IP65 (case closed) |
| Certification | CE |
| Sample pump | Included |
| Sample flow / fittings | 0.1 to 3 l/min · for 6 mm O.D. tubing |
| Options | Flow sensor |
Operating conditions
| Feature | Detail |
|---|---|
| Sample gas pressure | 0.1 to 0.3 bar (relative) |
| Sample gas temperature | 5 to 40 °C |
| Sample gas characteristics | Dry, oil-free, dust-free |
| Operating temperature | 0 to 50 °C |
| Humidity / altitude | ≤ 95% RH non-condensing / -300 to 3000 m |
| Calibration | Zero with N2; span with a CH4 cylinder |
| Warm-up time | 30 s to start |
Analytical performance
| Feature | Detail |
|---|---|
| Measuring principle | TDLAS (tunable diode laser absorption spectroscopy) |
| Measured gas | CH4 |
| Measuring range | 0-100 ppm up to 0-40,000 ppm |
| Precision | ≤ 0.8 ppm or 0.6% of reading |
| Accuracy | ±2% of full scale (or ±2 ppm / 2% of reading, whichever is greater) |
| Response time (T90) | ≤ 1.8 s |
Ranges, precision and response time as specified for the laser sensor.
Options and accessories
How TDL laser spectroscopy works
TDLAS (tunable diode laser absorption spectroscopy) tunes a diode laser across a very narrow absorption line of the target gas: the laser line is much narrower than the absorption line of the gas, so the resolution is much higher than with other technologies, and the analyzer detects specific compounds selectively, in real time and with minimal interference, even at ppm concentrations.
The laser sensor is chosen for the gases to be measured. TDL technology does not require frequent calibrations, which keeps maintenance and running costs low.
Other ETG 6900 formats
Need to measure other gases, or work in a plant? The ETG 6900 series offers the same TDL laser technology in rack, portable and wall-mounted formats.