TDL laser gas analyzer: one technology, three formats
TDL laser gas analyzer · selective, real-time measurement down to ppm levels · rack, portable and wall-mounted

ETG 6900 is the TDL laser gas analyzer developed by ETG Risorse e Tecnologia. A tunable diode laser detects specific gases selectively and in real time, down to ppm levels, with very fast response, minimal interference and little maintenance.
The same laser technology is available in three formats, to suit fixed installations, field measurements and plants: 19" rack, portable and wall-mounted cabinet. The laser sensor is selected for the gas or gases you need to measure.
Three formats of the ETG 6900 analyzer

ETG 6900 19 – rack analyzer

ETG 6900 P – portable analyzer

ETG 6900 WM – wall-mounted analyzer
How TDL laser spectroscopy works
TDLAS (tunable diode laser absorption spectroscopy) tunes a diode laser across a very narrow absorption line of the target gas: the laser line is much narrower than the absorption line of the gas, so the resolution is much higher than with other technologies, and the analyzer detects specific compounds selectively, in real time and with minimal interference, even at ppm concentrations.
The laser sensor is chosen for the gases to be measured. TDL technology does not require frequent calibrations, which keeps maintenance and running costs low.
Gases measured by the ETG 6900
The laser sensor is chosen for the gas or gases to be measured. These are the available configurations; values are common to the three formats.
| Feature | Detail |
|---|---|
| Measuring principle | TDLAS (tunable diode laser absorption spectroscopy) |
| Accuracy | ±2% of full scale (or ±2 ppm / 2% of reading, whichever is greater) |
| CH4 | 0-100 ppm up to 0-40,000 ppm · precision ≤ 0.8 ppm or 0.6% of reading · T90 ≤ 1.8 s |
| CH4 + CO2 | CH4 0-100 ppm, CO2 0-10% vol · precision CH4 ≤ 0.8 ppm, CO2 ≤ 2,000 ppm · T90 ≤ 30 s (0.3 l/min) |
| CH4 + C2H6 | CH4 0-100 ppm up to 0-40,000 ppm, C2H6 0-1,000 ppm · T90 CH4 ≤ 1.8 s, C2H6 ≤ 15 s |
| NH3 + H2O | NH3 0-100 ppm, H2O 0-5% vol · precision NH3 ≤ 0.8 ppm, H2O ≤ 0.2% vol · T90 ≤ 3 s |
| C2H2 + H2O | C2H2 0-100 ppm (linear up to 500 ppm), H2O 0-10% vol · T90 60 s (0.6 l/min) |
| H2O (-H) | 0-30% vol · accuracy ±0.5% vol · precision 0.2% vol (1 s) / 0.1% vol (10 s) · T90 2 s (3 l/min) |
| NH3 + H2O (-H) | NH3 0-100 ppm (min. range 0-20 ppm), H2O 0-30% vol · NH3 precision 1.8 ppm (1 s) / 0.8 ppm (10 s) · T90 2 s (3 l/min) |
| HCl + H2O (-H) | HCl 0-50 ppm (linear up to 500 ppm, no precision guarantee), H2O 0-30% vol · detection limit < 0.4 ppm, precision < 0.6 ppm (10 s avg.), accuracy ±2 ppm · T90 20 s (3 l/min) |
Ranges, precision and response times as specified for each laser sensor. The heated-cell (-H) configuration includes a heated measuring cell (190 °C), a heated sample pump (if a pump is installed) and a heated sample line (mandatory).
Heated-cell (-H) configuration
Applications of the ETG 6900 gas analyzer
Industrial emissions monitoring
Greenhouse gas monitoring
Fugitive methane emissions
Many other applications
Leak checks, gas purity control, CO2 quality control, process monitoring and research: the laser sensor is chosen for the compound to be measured.
Why choose ETG 6900
- Selective detection of specific gases, with minimal interference
- Real-time measurement with very fast response
- ppm-level sensitivity
- Little maintenance: no frequent calibrations
- Three formats: rack, portable and wall-mounted
- Heated-cell (-H) configuration for hot, wet gases
- Customizable options and industrial communication protocols