ETG 6900 – TDL Laser Gas Analyzer
TDL laser gas analyzer

TDL laser gas analyzer: one technology, three formats

TDL laser gas analyzer · selective, real-time measurement down to ppm levels · rack, portable and wall-mounted

ETG 6900 TDL laser gas analyzer family: portable, 19-inch rack and wall-mounted cabinet versions

ETG 6900 is the TDL laser gas analyzer developed by ETG Risorse e Tecnologia. A tunable diode laser detects specific gases selectively and in real time, down to ppm levels, with very fast response, minimal interference and little maintenance.

The same laser technology is available in three formats, to suit fixed installations, field measurements and plants: 19" rack, portable and wall-mounted cabinet. The laser sensor is selected for the gas or gases you need to measure.

TDLAS
Laser technology
Selective detection
ppm
Detection level
Real-time measurement
3 Formats
Rack · Portable · Wall
One laser technology
190 °C
Heated cell (-H)
For hot, wet gases
Choose your format

Three formats of the ETG 6900 analyzer

Only methane to measure? The ETG 6900 P CH4 is the compact, battery-powered portable TDL analyzer dedicated to CH4, ideal for leak detection.
The technology

How TDL laser spectroscopy works

TDLAS (tunable diode laser absorption spectroscopy) tunes a diode laser across a very narrow absorption line of the target gas: the laser line is much narrower than the absorption line of the gas, so the resolution is much higher than with other technologies, and the analyzer detects specific compounds selectively, in real time and with minimal interference, even at ppm concentrations.

The laser sensor is chosen for the gases to be measured. TDL technology does not require frequent calibrations, which keeps maintenance and running costs low.

Gases and performance

Gases measured by the ETG 6900

The laser sensor is chosen for the gas or gases to be measured. These are the available configurations; values are common to the three formats.

FeatureDetail
Measuring principleTDLAS (tunable diode laser absorption spectroscopy)
Accuracy±2% of full scale (or ±2 ppm / 2% of reading, whichever is greater)
CH40-100 ppm up to 0-40,000 ppm · precision ≤ 0.8 ppm or 0.6% of reading · T90 ≤ 1.8 s
CH4 + CO2CH4 0-100 ppm, CO2 0-10% vol · precision CH4 ≤ 0.8 ppm, CO2 ≤ 2,000 ppm · T90 ≤ 30 s (0.3 l/min)
CH4 + C2H6CH4 0-100 ppm up to 0-40,000 ppm, C2H6 0-1,000 ppm · T90 CH4 ≤ 1.8 s, C2H6 ≤ 15 s
NH3 + H2ONH3 0-100 ppm, H2O 0-5% vol · precision NH3 ≤ 0.8 ppm, H2O ≤ 0.2% vol · T90 ≤ 3 s
C2H2 + H2OC2H2 0-100 ppm (linear up to 500 ppm), H2O 0-10% vol · T90 60 s (0.6 l/min)
H2O (-H)0-30% vol · accuracy ±0.5% vol · precision 0.2% vol (1 s) / 0.1% vol (10 s) · T90 2 s (3 l/min)
NH3 + H2O (-H)NH3 0-100 ppm (min. range 0-20 ppm), H2O 0-30% vol · NH3 precision 1.8 ppm (1 s) / 0.8 ppm (10 s) · T90 2 s (3 l/min)
HCl + H2O (-H)HCl 0-50 ppm (linear up to 500 ppm, no precision guarantee), H2O 0-30% vol · detection limit < 0.4 ppm, precision < 0.6 ppm (10 s avg.), accuracy ±2 ppm · T90 20 s (3 l/min)

Ranges, precision and response times as specified for each laser sensor. The heated-cell (-H) configuration includes a heated measuring cell (190 °C), a heated sample pump (if a pump is installed) and a heated sample line (mandatory).

Hot and wet gases

Heated-cell (-H) configuration

For hot, wet samples, the heated-cell (-H) configuration keeps the measuring cell at 190 °C and accepts up to 30% vol of water vapour. It includes a heated sample pump (if a pump is installed) and a heated sample line, which is mandatory. A heated portable probe is available as an option. The configuration is offered on all three formats.
Where it is used

Applications of the ETG 6900 gas analyzer

Emissions & processes

Industrial emissions monitoring

Selective, real-time measurement of NH3, HCl and H2O in flue gas and process streams, with the heated-cell (-H) configuration for hot, wet gases. See industrial emissions monitoring.
Environment

Greenhouse gas monitoring

Low detection limits for CH4 and CO2, to keep fugitive emissions from landfills, networks and plants under control. See greenhouse gas emissions.
Energy

Fugitive methane emissions

Locating fugitive CH4 emission points in biogas plants and landfills, and studying CH4 emissions (e.g. university research).

Many other applications

Leak checks, gas purity control, CO2 quality control, process monitoring and research: the laser sensor is chosen for the compound to be measured.

Need to measure many gases at the same time? See the ETG 9500 FTIR multicomponent analyzer.
Key advantages

Why choose ETG 6900

  • Selective detection of specific gases, with minimal interference
  • Real-time measurement with very fast response
  • ppm-level sensitivity
  • Little maintenance: no frequent calibrations
  • Three formats: rack, portable and wall-mounted
  • Heated-cell (-H) configuration for hot, wet gases
  • Customizable options and industrial communication protocols