ETG 6900 19″ – Rack TDL Laser Gas Analyzer
19" rack TDL laser gas analyzer

19-inch rack TDL laser gas analyzer for selective, continuous measurement

TDL laser gas analyzer · 19" 4U rack · continuous measurement · ppm-level detection · heated cell for hot, wet gases

ETG 6900 19-inch rack TDL laser gas analyzer with 7-inch touch screen

ETG 6900 19" is the rack version of the TDL laser gas analyzer developed by ETG Risorse e Tecnologia. A tunable diode laser detects a specific gas selectively, in real time and down to ppm levels, with very fast response and little maintenance.

Housed in a standard 19" 4U rack enclosure with a 7" touch screen, it is made for fixed installations. Data are logged in .csv, with remote access via Ethernet or Wi-Fi. The laser sensor is selected for the gases you need to measure.

TDLAS
Tunable diode laser
Selective, real-time detection
19" 4U
Rack enclosure
483 × 177 × 550 mm · 11 kg
Touch 7"
Screen
Ethernet · USB · Wi-Fi
190 °C
Heated cell (-H)
For hot, wet gases
Key features

Built for fixed installations and continuous measurement

01

Selective

Laser spectroscopy detects specific gases with minimal interference, in real time and with little maintenance.
02

Rack-mounted

Standard 19" 4U rack, 483 × 177 × 550 mm and 11 kg, with a 7" touch screen for live values and trends.
03

Connected

Ethernet and Wi-Fi as standard; optional 4-20 mA outputs, digital alarm outputs and industrial protocols for SCADA integration.
Where it is used

Applications of the ETG 6900 19" gas analyzer

Emissions & processes

Industrial emissions monitoring

Selective, real-time measurement of NH3, HCl and H2O in flue gas and process streams, with the heated-cell (-H) configuration for hot, wet gases. See industrial emissions monitoring.
Environment

Greenhouse gas monitoring

Low detection limits for CH4 and CO2, to keep fugitive emissions from landfills, networks and plants under control. See greenhouse gas emissions.
Energy

Fugitive methane emissions

Locating fugitive CH4 emission points in biogas plants and landfills, and studying CH4 emissions (e.g. university research).

Many other applications

Leak checks, gas purity control, CO2 quality control, process monitoring and research: the laser sensor is chosen for the compound to be measured.

Hot or wet gas? The heated-cell (-H) configuration keeps the measuring cell at 190 °C and accepts up to 30% vol of water vapour. It includes a heated sample pump (if a pump is installed) and a heated sample line, which is mandatory.
Technical data

ETG 6900 19": key specifications

FeatureDetail
Power supply230 VAC 50 Hz (other mains voltages/frequencies on request)
Power consumption70 W (non-heated cell) / 170 W (heated cell) · heated line 80 W/m · heated probe 80 W
Display / connectivity7" touch screen; Ethernet, Wi-Fi, USB
Communication protocol4-20 mA analog outputs (optional); 4 digital alarm outputs (optional); industrial protocols (Modbus, Profibus, Profinet…) (optional): SCADA integration with bidirectional communication (control from SCADA possible)
Data availability.csv format, downloadable via USB or remote folder (SMB)
Dimensions (L × W × D) / weight483 × 177 × 550 mm (19" rack, 4U) · 11 kg
CertificationCE
Sample pumpOptional (heated pump with the heated cell)
Sample flow / fittings0.1 to 3 l/min (non-heated cell); 1.5 to 5 l/min (heated cell) · for 6 mm O.D. tubing
Laser sensorsOne laser sensor, selected for the gases to be measured

Operating conditions

FeatureDetail
Sample gas800-1100 mbar; ambient temperature (non-heated cell) or up to 190 °C (heated cell, -H)
Sample gas characteristicsOil-free, dust-free; non-condensing (non-heated cell) or up to 30% vol H2O (heated cell)
Measuring cell temperatureNot heated; 190 °C with heated cell (-H), up to 220 °C
Ambient conditions0 to 50 °C; ≤ 95% RH non-condensing; -300 to 3000 m
CalibrationZero with N2; span with a cylinder of the target gas
Warm-up time30 s to start; usable after about 3 min; stable after about 30 min (heated cell: about 30 min to reach 190 °C, fully stable after about 60 min)

Analytical performance

FeatureDetail
Measuring principleTDLAS (tunable diode laser absorption spectroscopy)
Accuracy±2% of full scale (or ±2 ppm / 2% of reading, whichever is greater)
CH40-100 ppm up to 0-40,000 ppm · precision ≤ 0.8 ppm or 0.6% of reading · T90 ≤ 1.8 s
CH4 + CO2CH4 0-100 ppm, CO2 0-10% vol · precision CH4 ≤ 0.8 ppm, CO2 ≤ 2,000 ppm · T90 ≤ 30 s (0.3 l/min)
CH4 + C2H6CH4 0-100 ppm up to 0-40,000 ppm, C2H6 0-1,000 ppm · T90 CH4 ≤ 1.8 s, C2H6 ≤ 15 s
NH3 + H2ONH3 0-100 ppm, H2O 0-5% vol · precision NH3 ≤ 0.8 ppm, H2O ≤ 0.2% vol · T90 ≤ 3 s
C2H2 + H2OC2H2 0-100 ppm (linear up to 500 ppm), H2O 0-10% vol · T90 60 s (0.6 l/min)
H2O (-H)0-30% vol · accuracy ±0.5% vol · precision 0.2% vol (1 s) / 0.1% vol (10 s) · T90 2 s (3 l/min)
NH3 + H2O (-H)NH3 0-100 ppm (min. range 0-20 ppm), H2O 0-30% vol · NH3 precision 1.8 ppm (1 s) / 0.8 ppm (10 s) · T90 2 s (3 l/min)
HCl + H2O (-H)HCl 0-50 ppm (linear up to 500 ppm, no precision guarantee), H2O 0-30% vol · detection limit < 0.4 ppm, precision < 0.6 ppm (10 s avg.), accuracy ±2 ppm · T90 20 s (3 l/min)

Ranges, precision and response times as specified for each laser sensor. The heated-cell (-H) configuration includes a heated measuring cell (190 °C), a heated sample pump (if a pump is installed) and a heated sample line (mandatory).

Options and accessories

Sample pumpHeated sample pumpHeated cell (-H)Heated lineHeated portable probe4-20 mA outputsDigital alarm outputsIndustrial protocols (Modbus / Profibus / Profinet)Multipoint sampling systemCalibration gas port inlet
How it works

How TDL laser spectroscopy works

TDLAS (tunable diode laser absorption spectroscopy) tunes a diode laser across a very narrow absorption line of the target gas: the laser line is much narrower than the absorption line of the gas, so the resolution is much higher than with other technologies, and the analyzer detects specific compounds selectively, in real time and with minimal interference, even at ppm concentrations.

The laser sensor is chosen for the gases to be measured. TDL technology does not require frequent calibrations, which keeps maintenance and running costs low.

ETG 6900 series

Three formats, one TDL laser technology

The ETG 6900 uses the same laser technology in every format: pick the one that fits your application.

ETG 6900 series

ETG 6900 P – portable

Rugged portable analyzer for measurements on site, mains-powered. Discover →
ETG 6900 series

ETG 6900 WM – wall-mounted

Wall-mounted cabinet for plants, with up to three laser sensors. Discover →

Need to measure many gases at the same time? See the ETG 9500 FTIR multicomponent analyzer.

Request information about the ETG 6900 19"
Tell us about your application: we will help you choose the laser sensor, the configuration and the options best suited to it.
Contact ETG