ETG 9500 Anesthetic Gases Monitors – FTIR Anesthetic Gas Monitoring
FTIR anesthetic gas monitors

FTIR anesthetic gas monitors for operating rooms: multipoint cabinet and portable analyzer

FTIR anesthetic gas monitoring · multi-gas analysis from a single spectrum · up to 48 sampling points · portable analyzer · software and algorithms developed by ETG

ETG 9500 anesthetic gas monitors: multipoint cabinet and portable analyzer

ETG 9500 anesthetic gas monitors are designed for the environmental monitoring of residual anesthetic gases in operating rooms and medical and laboratory environments. They are based on the ETG 9500 FTIR analyzer, integrated by ETG with software and algorithms developed by its in-house research and development team, and measure sevoflurane, isoflurane, desflurane, nitrous oxide, carbon dioxide and water vapor at the same time, from a single infrared spectrum.

Two systems share the same FTIR technology: a cabinet system with multipoint sampling for continuous monitoring of up to 48 points, and a portable analyzer for spot checks, with an optional multipoint case.

Multi-gas
Simultaneous analysis
One infrared spectrum
< 1 ppm
Detection capability
0.5 cm⁻¹ resolution
Up to 48
Sampling points
Cabinet system
2 Systems
Cabinet · Portable
Made in Italy
Choose your system

Two ETG 9500 systems for anesthetic gas monitoring

Continuous monitoring

Why monitor anesthetic gases continuously

Compared to periodic spot checks, a continuous monitoring system makes it possible to:

  • Detect both average exposure values (TWA) and peak values, both used as reference by industry guidelines for assessing the risk of exposure to anesthetic gases
  • Build a historical data record useful for audits, inspections and reporting
  • Trigger automatic real-time alarms whenever configured thresholds are exceeded
  • Verify, under real operating conditions, the effectiveness of air exchange and waste anesthetic gas evacuation (scavenging) systems, promptly identifying leaks or ventilation anomalies

The portable analyzer is the right tool for periodic exposure checks, verification after a suspected leak or an equipment change, and rooms without a fixed monitoring system.

The technology

How FTIR spectroscopy works

With FTIR (Fourier transform infrared) spectroscopy every compound absorbs infrared radiation at specific frequencies: analyzing the whole spectrum gives the concentration of every gas, all at the same time and continuously.

The ETG 9500 FTIR analyzer has a 0.5 cm⁻¹ resolution and a 5-metre optical path in a low-volume cell, for high selectivity and sensitivity, with detection limits well below 1 ppm. Automatic background acquisition, internal filters, cleaning valves and temperature and pressure control keep performance stable over time.

FTIR vs other techniques

Advantages of FTIR over NDIR, gas chromatography and photoacoustic spectroscopy

Anesthetic gas monitoring has historically relied on NDIR analyzers, gas chromatography (GC) and, more recently, photoacoustic spectroscopy (PAS) with an infrared source. NDIR and PAS systems are generally based on a dedicated optical filter for each measured gas; the FTIR analyzer acquires the entire infrared spectrum and derives the concentration of all compounds of interest at once.

vs NDIR

One analyzer, many gases

A single analyzer measures sevoflurane, isoflurane, desflurane, nitrous oxide, carbon dioxide and water vapor without a dedicated sensor or filter for each gas. The 0.5 cm⁻¹ resolution separates halogenated anesthetics with partially overlapping bands, reducing the cross-interference typical of filter-based systems.
vs gas chromatography

Faster, no carrier gas

Analysis times are much shorter than a gas chromatograph, which needs a separation cycle for each measurement. No Helium or Hydrogen carrier gas, and no columns to replace: lower running costs over time.
vs photoacoustic (PAS)

Constant time, no alcohol interference

Measurement time does not grow with the number of gases. The full spectrum recognizes isopropanol and other alcohols from disinfectants as such, instead of counting them as anesthetic gas: in optical-filter photoacoustic systems this interference is documented in the scientific literature (Herzog-Niescery et al., BMC Anesthesiology, 2019): sevoflurane peaks of about 15 ppm, falling below 1 ppm once the alcohol peaks are removed.
  • New gases or different measuring ranges are added by software, even remotely over a LAN, with no hardware change
  • The full spectrum is stored: historical data can be re-analyzed later, even for compounds not originally configured
  • Sub-ppm detection limits, kept in the presence of humidity and carbon dioxide
Where it is used

Application: anesthetic gas monitoring in operating rooms

Operating rooms, recovery rooms and any room where anesthetic gases are used: see the anesthetic gas monitoring application for details.

ETG 9500 anesthetic gas monitors are measuring instruments for occupational exposure monitoring. They are not medical devices under Regulation (EU) 2017/745: they have no diagnostic or therapeutic purpose on the patient and are not intended for monitoring vital signs.
Request information about the ETG 9500 anesthetic gas monitors
Tell us about your operating rooms: we will help you choose the most suitable system and configuration.