Chemical Process and Process Gas Monitoring

In chemical and pharmaceutical plants many process gases must be measured directly on the process, at ppm level and with a very fast response. ETG laser analyzers and FTIR cover moisture, acetylene, ammonia, hydrogen chloride and methane, and many other compounds.

ppm
Measurement level
Laser TDL
190 °C
Heated cell
ETG 6900 -H
Up to 50
Gases at once
ETG 9500 FTIR
3
Formats
Rack · wall · portable
Why measure

Why measure process gases

In a chemical plant the composition of the gas decides the yield, the quality of the product and the safety of the process. Moisture in a process gas can spoil a reaction or corrode the plant; acetylene is unstable and flammable and must be controlled in production and use; ammonia and hydrogen chloride are toxic and corrosive and must be kept under control in plants and refrigeration circuits.

Measuring directly on the process, with a fast response, lets you act before a deviation becomes a loss of product or a safety event.

Process control

Yield and quality

Fast measurements keep reactions and separations within their operating window.
Safety

Flammable and toxic gases

Detect acetylene, ammonia and hydrogen chloride deviations at ppm level.
Moisture

Dry gas streams

Measure water vapour in process gas to protect catalysts, products and pipework.
Emissions

Off-gas and stacks

Verify what leaves the plant with the same instruments.
Chemical plant
Process gas monitoring in chemical plants
What is measured

Laser and FTIR measurement of process gases

The ETG 6900 laser analyzer uses a TDL sensor matched to the gas to be measured: NH3 with water vapour, HCl with water vapour, CH4, CH4 with CO2 or ethane, and C2H2 with water vapour. The measurement is selective and fast, and a heated cell, pump and line at 190 °C handle hot, wet and corrosive gases.

Where many compounds change at once, or a gas purity must be verified, the ETG 9500 FTIR measures up to 50 gases from a single spectrum. For combustion and process gases, the ETG 7600 measures CO and CO2 by NDIR and SO2, nitrogen oxides and hydrocarbons by NDUV, on one or more measuring points in sequence.

ETG analyzerTechnologyTypical gasesBest for
ETG 6900TDL laserNH3+H2O, HCl+H2O, CH4, C2H2+H2OFast selective measurement directly on the process
ETG 9500 FTIRFTIRUp to 50 gasesMany compounds at once, gas purity
ETG 7600NDIR / NDUVCO, CO2, SO2, NOx, hydrocarbonsCombustion and process gases, several points in sequence

Other gases, ranges and sample treatment systems on request.

ETG solutions

ETG analyzers for chemical plants

Choose the laser analyzer for fast measurements of a specific gas, the FTIR for many compounds, the 7600 for combustion gases. All can communicate with SCADA.

Available formats

ETG 6900 — Rack 19" · Wall-mount · Portable

ETG 9500 FTIR — Rack 19" · Wall-mount · Portable

Spot measurements or temporary campaigns? The portable versions (P) offer the same analytical performance as the fixed versions.

FAQ

Frequently asked questions

Which process gases can the laser analyzer measure?
Ammonia with water vapour, hydrogen chloride with water vapour, methane, methane with carbon dioxide or ethane, and acetylene with water vapour, depending on the laser sensor chosen.
Can it work on hot, wet and corrosive gas?
Yes: the ETG 6900 -H has a heated cell, pump and line at 190 °C (220 °C on request) and an optional heated probe.
When is the FTIR the better choice?
When many compounds must be measured together or the gas purity must be checked: it measures up to 50 gases at once.
Do you supply the sampling system?
Yes. ETG customises the instrumentation and supplies complete sampling and analysis systems according to the process.

Related applications

See also industrial emissions monitoring, DeNOx and ammonia slip control and gas purity analysis.

Talk to an ETG specialist
Describe your process and the gases to be measured: we will propose the right analyzer and sampling system.
Contact ETG