In chemical and pharmaceutical plants many process gases must be measured directly on the process, at ppm level and with a very fast response. ETG laser analyzers and FTIR cover moisture, acetylene, ammonia, hydrogen chloride and methane, and many other compounds.
Why measure process gases
In a chemical plant the composition of the gas decides the yield, the quality of the product and the safety of the process. Moisture in a process gas can spoil a reaction or corrode the plant; acetylene is unstable and flammable and must be controlled in production and use; ammonia and hydrogen chloride are toxic and corrosive and must be kept under control in plants and refrigeration circuits.
Measuring directly on the process, with a fast response, lets you act before a deviation becomes a loss of product or a safety event.
Yield and quality
Flammable and toxic gases
Dry gas streams
Off-gas and stacks

Laser and FTIR measurement of process gases
The ETG 6900 laser analyzer uses a TDL sensor matched to the gas to be measured: NH3 with water vapour, HCl with water vapour, CH4, CH4 with CO2 or ethane, and C2H2 with water vapour. The measurement is selective and fast, and a heated cell, pump and line at 190 °C handle hot, wet and corrosive gases.
Where many compounds change at once, or a gas purity must be verified, the ETG 9500 FTIR measures up to 50 gases from a single spectrum. For combustion and process gases, the ETG 7600 measures CO and CO2 by NDIR and SO2, nitrogen oxides and hydrocarbons by NDUV, on one or more measuring points in sequence.
| ETG analyzer | Technology | Typical gases | Best for |
|---|---|---|---|
| ETG 6900 | TDL laser | NH3+H2O, HCl+H2O, CH4, C2H2+H2O | Fast selective measurement directly on the process |
| ETG 9500 FTIR | FTIR | Up to 50 gases | Many compounds at once, gas purity |
| ETG 7600 | NDIR / NDUV | CO, CO2, SO2, NOx, hydrocarbons | Combustion and process gases, several points in sequence |
Other gases, ranges and sample treatment systems on request.
ETG analyzers for chemical plants
Choose the laser analyzer for fast measurements of a specific gas, the FTIR for many compounds, the 7600 for combustion gases. All can communicate with SCADA.

ETG 6900

ETG 9500 FTIR

ETG 7600
ETG 6900 — Rack 19" · Wall-mount · Portable
ETG 9500 FTIR — Rack 19" · Wall-mount · Portable
Spot measurements or temporary campaigns? The portable versions (P) offer the same analytical performance as the fixed versions.
Frequently asked questions
Which process gases can the laser analyzer measure?
Can it work on hot, wet and corrosive gas?
When is the FTIR the better choice?
Do you supply the sampling system?
Related applications
See also industrial emissions monitoring, DeNOx and ammonia slip control and gas purity analysis.